etox-logo
ETOXInformationssystem
Ökotoxikologie und
Umweltqualitätsziele

Test

Identifikationsnummer 109438
Stoff 2,4,6-Trinitrotoluol
Literaturtitel Toxicity and fate of two munitions constituents in spiked sediment exposures with the marine amphipod Eohausorius estuaries
Organismus Eohaustorius estuarius
Habitat Sediment
Prüfart Mortalität
Endpunkt
Standard EPA 600/R-94/025
Dauer Parameter Wert Bezug nominal / analytisch
10  d LR50 = 2,497  mg/kg FG real
Dauer (norm.) Wert (norm.)
10  d LR50 = 2,497  mg/kg FG real
Testmedium Sediment
pH 7,6 - 8,2 Temperatur 14,8 - 16,1 °C
Bodenart KAK
Corg [%] 0,36 Ton [%] 23

Methodenlisting

Durchführung 1-L glass beakers containing 200 g of spiked sediment and 800 ml of 20‰ synthetic seawater. Five replicates per test concentration.
Auswertung (Statistische Methode) trimmed Spearman-Karber Method
Futter without feeding
Konzentrationsbestimmung sum-molar concentrations of 2,4,6-trinitrotoluene (TNT) and TNT degradation products = TNT*
Matrixbezug Tissue. Wet weight basis.
Organismus Alter/Lebenstadium 3 - 5 mm
Organismus Herkunft clean field site, acclimated slowly to the 20‰ experimental salinity
Testsubstanz Radiolabeled trinitrotoluene ([14C]TNT, 23.6 Ci/mol) New England Nuclear Research Products and Nonradiolabeled TNT (99% pure) Chem Service
Sauerstoffgehalt 8,1 - 9,8 mg/l
Testsubstanz, Reinheit radiochemical purity (99%) and nonradiolabeled TNT (99%)
Analytik der Testsubstanz Yes. liquid scintillation counting (LSC), and high-performance liquid chromatography (HPLC)
Lösevermittler acetone
Konzentrationen, nominal 25 | 50 | 100 | 200 | 400 | mg/kg dry wt (sediment SDB)
Kontrollen (negative) survival 82 +/- 8%
Testmedium Uncontaminated surficial sediments, (total solids content 5 67%; silt and clay content 5 23%; total organic carbon content 5 0.36%), San Diego Bay (SDB), California, USA. Collection-site sediment (YB) was used as the negative control.
Lösungsmittelkontrolle, Ergebnis nr
Salzgehalt 20 g/l

Memos

Bemerkung LR50 = 11,7 (4,7–29,1) µmol/kg wet wt

Testbonität

RI-3 / CRED
Ableitung Nein. Da ein straker und nicht linearer Abbau von TNT in den Testansätzen auftrat.